BP3V-S Open Circuit Pump
Specification: 75/280 cc/rev
Rated pressure: 350 bar
Peak pressure: 400 bar
Swash-plate design, applied in open circuit hydraulic systems
WHAT WE CAN DO
Specification: 75/280 cc/rev
Rated pressure: 350 bar
Peak pressure: 400 bar
Swash-plate design, applied in open circuit hydraulic systems
Higher working pressure, rated working pressure up to 350 bar.
Higher efficiency, improved by 2% ~ 3% than similar products.
Compact design to meet tight installation space requirements, optimized axial structure with 10% shorter total length than the last generation HP3V series.
Optimized port plate, lower noise.
Heavy-duty bearings and increased drive shaft dimension for higher load and longer life time.
Various controllers suitable for requirements of all kinds of applications.
Specification | BP3V 75S | BP3V 280S | |
Displacement (cc/rev) | 75 | 280 | |
Speed | Rated speed (rpm) | 2450 | 2000 |
Maximum speed (rpm) | 3000 | 2000 | |
Pressure | Rated pressure (bar) | 350 | 350 |
Maximum pressure (bar) | 400 | 400 | |
Maximum torque (N•m) | 415 | 1570 | |
Case volume (L) | 1.3 | 3.2 | |
Suction port pressure (abs bar) | 0.8 | ||
Drain pressure | Rated pressure (bar) | 1 | |
Maximum pressure (bar) | 3 | ||
Hydraulic fluid viscosity range (mm2/s) | 10~1000 (optimum viscosity range 16 ~ 36) | ||
Temperature range ( ℃ ) | -30~80 | ||
Mass (Kg) | 59 | 160 |
Mainly applied in construction machinery and materials handling industries, such as:
Concrete Pump